Disabled Toilet Alarm System

When someone falls or feels unwell in an accessible toilet, the first problem is that nobody outside knows. A disabled toilet alarm system fixes that: one pull of the cord sets off a light and sounder where staff or family will notice it, and the alarm stays on until someone comes in and resets it.

Flex Access supplies and installs complete 1 to 4 zone disabled toilet alarm systems for homes, clinics, hotels, offices and public buildings across the UAE, from the site survey through to a tested, working system.

Can be used at

CATEGORIES-01

House

CATEGORIES-02

Business

Your are here

Features

  • Simple 3 wire operation for all field devices
  • Control Panel supporting up to 4 zones
  • Simple maintenance and fault diagnosis
  • On board buzzer in both Control Panel & Remote Indicator
  • Zone LED indication on Control Panel
  • Full range of field devices available (i.e. Pull Cord, Remote Reset & Remote Indicator)

Introduction

This Disabled Persons Toilet Alarm Kit is available in 1, 2, 3 or 4 zones (where one zone is used for each toilet). It has been designed for use in disabled persons dwellings typically for disabled toilets where this design process considered the requirements of BS8300. The system consists of a 4 zone control panel (DPTA-CP4) which is (for each zone) connected to a Pull Cord (DPTA-PC), Remote Reset (DPTA-RR) and Remote Indicator (DPTA-RI). These connected items are known as fi eld devices which provide the Control Panel with the necessary input and output signals to allow the system to function. These fi eld devices are categorised as follows;
  1. Pull Cords (DPTA-PC) are “Call Devices” which are ceiling
    mounted pull cords used to generate an alarm activation
    by a person in distress or requiring attention from a
    carer. When a call devices is activated the system will
    generate an alarm and the Remote Indicator (DPTA-RI)
    will illuminate & sound.
  2. Remote Resets (DPTA-RR) are “Reset Devices” which are
    generally wall mounted and consist of a push button
    which is pressed to cancel an alarm activation.
  3.  Remote Indicators (DPTA-RI) are “Warning Devices”
    that are generally wall mounted devices which during
    an alarm activation will alert cares / staff of a person
    requiring attention. Warning devices typically have
    visual and audible element within the same housing,
    but devices with only audible or visual elements may be
    fitted to a system.
  4. The control panel (DPTA-CP) is powered by mains supply
    and an optional battery back-up can be installed which
    allows the system to function during a power outage.

Electrical Requirements

  • A. Power Supply
  • 230V AC at 50/60Hz
  • 12V DC Storage battery
  • Standby Current : 4mA
  • Alarm Current : 250mA (max)
Disabled Toilet Alarm

How the toilet alarm system works

Help arrives because the alarm cannot be missed or switched off by accident. Each toilet is one zone, and each zone runs through the same four steps.

  1. Call

    The person pulls the ceiling-mounted cord. It reaches down to the floor, so it works from the WC, a wheelchair or after a fall.

  2. Alert

    The remote indicator outside the toilet flashes and sounds, and the control panel shows which zone is calling.

  3. Response

    Staff or a family member go to that toilet. The alarm keeps sounding until they arrive.

  4. Reset

    The responder presses the reset button inside the toilet, so the alarm only clears once someone has checked on the person.

What is in the disabled toilet alarm kit

Every component has one job, and all of them run on simple 3-wire cabling.

ComponentCodeWhat it doesWhere it goes
Pull cordDPTA-PCRaises the alarmCeiling, inside the toilet, cord reaching the floor
Remote resetDPTA-RRCancels the alarm once help arrivesWall, inside the toilet, within reach of the WC
Remote indicatorDPTA-RIFlashes and sounds to alert staffWall, outside the toilet or where staff are
Control panelDPTA-CP4Powers the system and shows the calling zone on its LEDsStaff area, reception or plant room

The panel and the remote indicator both carry an on-board buzzer, and fault diagnosis is done from the panel, which keeps maintenance quick.

Choose your system: 1 to 4 zones

One zone covers one toilet, so the right kit is simply the number of accessible toilets you need to monitor from one point.

KitZonesTypical site
DPTA-KIT11Villa, apartment, small clinic or shop
DPTA-KIT22Office floor or restaurant with male and female accessible WCs
DPTA-KIT33Small hotel or medical centre
DPTA-KIT44Mall level, school or hospital wing

Where the UAE expects an emergency alarm

If your building is inspected for accessibility, the toilet alarm is one of the items checked. The requirement depends on the building type.

01

Healthcare in Dubai

The Dubai Health Authority checklist for People of Determination in hospitals, day surgical centres and outpatient facilities requires accessible restrooms to have a toilet with an emergency call bell (section C.8).

Source: DHA checklist

02

Hotels in Dubai

The Dubai Universal Design Audit Guide lists a toilet with an alarm string in accessible hotel rooms (item ARh3), and an emergency call button or rope in full family toilets (item SPff5).

Source: Dubai Municipality guide

03

Layout to BS 8300

Neither UAE document sets mounting details, so designers follow BS 8300-2:2018 (section 13.7.2): a red cord with two red bangles, reachable from the WC and from the floor, kept within 50 mm of the adjacent wall where a transfer happens, and a reset button next to the WC.

Source: Installer guidance on BS 8300

This kit was designed with the BS 8300 requirements in mind. Requirements for your emirate and building type are confirmed during the site assessment.

Technical specifications

SpecificationValue
Zones1, 2, 3 or 4 (one per toilet)
Mains supply230V AC, 50/60Hz
Battery backupOptional 12V DC, keeps the system running in a power cut
Standby current4mA
Alarm current250mA maximum
Wiring3-wire to all field devices
IndicationZone LEDs on panel, light and sounder on remote indicator
Design basisBS 8300

Disabled toilet alarm installation, start to finish

You deal with one team from survey to sign-off, so nothing falls between the supplier and the electrician.

  1. Free site assessment

    We check the toilet layout, cable routes and where staff will see the indicator.

  2. Written quote

    You receive the zone count, positions and full cost in writing within 48 hours

  3. Installation

    Cord, reset, indicator and panel fitted and wired.

  4. Commissioning

    Every zone is tested from call to reset, and your staff are shown how to respond and reset.

  5. Aftercare

    Periodic testing and repairs. Repair and maintenance →

Why choose Flex Access as your disabled toilet alarm system supplier in UAE

An alarm only matters if it is installed where it can actually be reached and heard.

Flex Access is an accessibility specialist, not a general electrical trader, so the alarm is planned together with the grab rails, door, turning space and WC position.

See our accessible bathroom case study →

  • Based in Abu Dhabi, installing across UAE
  • Fitted alongside our accessible bathroom installations →
  • Advice from accessibility consultant Nouh Aqra on what your building type requires
  • Suitable for homes and businesses, including healthcare and hospitality

Disabled toilet alarm system FAQs

Who supplies disabled toilet alarm systems in the UAE?

Flex Access supplies and installs disabled toilet alarm systems, also called handicap toilet alarm systems, across the UAE. Each project starts with a free site assessment and a written quote.

Is a disabled toilet alarm required in the UAE?

For many buildings, yes. The DHA checklist for healthcare facilities requires an emergency call bell in accessible restrooms, and the Dubai Universal Design Audit Guide lists an alarm string in accessible hotel room toilets.

Where should the pull cord and reset button be installed?

Following BS 8300-2:2018, the red pull cord should be reachable from the WC and from the floor, and the reset button should sit on the wall next to the WC. The remote indicator goes outside the toilet where staff will see and hear it.

How many zones do I need?

One zone per accessible toilet. Kits come in 1, 2, 3 or 4 zones, all monitored from one control panel.

Does the alarm work during a power cut?

Yes, if the optional 12V DC battery backup is fitted. The system normally runs on 230V AC mains.

How is the alarm turned off?

Only by pressing the reset button inside the toilet. This means the alarm cannot be cleared until someone has gone in and checked on the person.

Make sure the next call for help is heard

Book a free site assessment and get a written quote for the right disabled toilet alarm system.